69kV, 600A & 1200A, Laminated Wood Pole
SK951108 - 1CD
138kV, 600A & 1200A, Laminated Wood Pole
SK940408 - 1CD
15kV, 600A & 1200A, Wood Pole
SK42574 - 1CD
69kV, 600A & 1200A, Wood Pole
SK000514 - 1CD
161kV, 600A & 1200A, Wood Pole
SK010202 - 1CD
34kV, 600A & 1200A, Concrete Pole
SK970915 - 1CD
69kV, 600A & 1200A, Concrete Pole
SK920310 - 1CD
115kV, 1200A, Concrete Pole
SK020915 - 1CD
138kV, 1200A, Concrete Pole
SK970624 - 1CD
115kV, 1200A
SK030505 - 1CD
46kV, 600A & 1200A, Light Duty
SK990201 - 1CD
69kV, 600A & 1200A, Light Duty
SK980618 - 1CD
138kV, 1200A, Light Duty
SK940924 - 1CDF
34kV, 600A, Wood Pole
SK950317 - 1CDF
46kV, 600A & 1200A, Wood Pole
SK840803 - 1CDF
69kV, 600A & 1200A, Wood Pole
SK020615 - 1CDF
115kV, 1200A, Concrete Pole
SK930704 - 1CDF
161kV, 1200A
SK951112 - 1CDT
138kV, 1200A, Laminated Wood Pole
SK980406 - 1CDT
46kV, 600A & 1200A, Wood Pole
SK800227 - 1CDT
69kV, 600A & 1200A, Wood Pole
SK7375 - 1CDT
115kV, 600A & 1200A, Wood Pole
SK960826 - 1CDT
46kV, 600A & 1200A, Concrete Pole
SK011017 - 1CDT
46kV, 600A & 1200A
SK970626 - 1CDT
69kV, 600A & 1200A
SK930809 - 1CDT
161kV, 600A & 1200A
SK000820 - 1CDT
69kV, 600A & 1200A, Light Duty
SK980501 - 1CDT
115kV, 600A & 1200A, Light Duty
SK971204 - 1CDT
138kV, 600A & 1200A, Light Duty
Transmission
Aluminum 1CSB
Aluminum 1ASB
Copper 1D Style
Copper 1CD Style
Copper 1AD Style
![]() 1CDOne Way |
![]() |
Type 1CD, 1-way,
copper side break switch
Type: 1CD
Orientation: Phase-over-phase or delta mounting
Ratings:15kV through 161kV
Ratings A: 600, 1200 and 2000 Amperes
Turner's Type 1CD side break switch is well suited for phase-over-phase applications, phase-next-to-phase and triangular configurations on the transmission system. Unlike many so-called transmission-switching products that are merely substation switches modified for use on the transmission system, the Type 1CD is a true transmission switch. It is designed and built for the harsh environmental conditions, galloping conductors and constant pole movement inherent in severe aerial applications.
The 1CD switch configuration is the most versatile. Designed as a "stock switch" suitable for almost any application, The conductor deadends right to the frame. Phase-over-phase, pole-saving triangular and delta mouting configurations are available. Line configurations such as tangent and 90-degree corner are easily handled. If the line is to be deadended to the pole, a "front mount" frame which moves the vertical operating pipe off of the thru-line pole face is available.
Turner Type 1CD switches can be used for station isolating and bypassing, distribution and transmission line sectionalizing or isolating arrestors, metering equipment and other apparatus. Right hand or left hand opening can be specified at time of order. They are easily upgraded for automatic operation and load breaking.
Secure Blade Closing
Turner Type 1CD switches firmly close into position, with the blade tip engaging the jaws with sufficient force to expand the contact jaws, preventing any blade bounce. Both the blade and jaw contacts are wiped clean during the closing action to ensure a low resistance current transfer. A heavy-duty blade-locking device keeps the blade closed despite temporary faults, surge currents, twisting structures or galloping conductors.
The lock is released during the switch opening sequence. This action, exclusive to Turner 1CD switches, breaks up any ice or contamination, and releases the contact friction, allowing the blade to easily be removed from the contacts.
Make Your Side Break a Load-Break Switch
For more than 35 years, Turner Electric's TECO-Rupter® Vacuum Interrupters have been the technology of choice for loop and load-break applications because of their current-interrupting ability, superior reliability and ease of application.
The TECO-Rupter offers industry leading performance levels including superior TRV ratings compared to other load-break technologies such as SF6, longer service life and greater interrupting capacity. No other load-break device provides 5,000 full load operations at either 2,000 or 3,000 Ampere ratings and a TRV rating up to 57kV.
Ordering Information | |||||||
| Switch Rating | Station Post Insulators | Catalog Number | |||||
| Voltage | Continuous Current | Peak Amps | Technical Reference # | Phase-Over-Phase Mounting | Delta Mounting | ||
| 15kV | 600 | 65,000 | TR205 | 1CD01506 | 1CDT01506 | ||
| 1200 | 99,000 | 1CD01512 | 1CDT01512 | ||||
| 2000 | 164,000 | 1CD01520 | 1CDT01520 | ||||
| 23kV | 600 | 65,000 | TR208 | 1CD02306 | 1CDT02306 | ||
| 1200 | 99,000 | 1CD02312 | 1CDT02312 | ||||
| 2000 | 164,000 | 1CD02320 | 1CDT02320 | ||||
| 34kV | 600 | 65,000 | TR210 | 1CD03406 | 1CDT03406 | ||
| 1200 | 99,000 | 1CD03412 | 1CDT03412 | ||||
| 2000 | 164,000 | 1CD03420 | 1CDT03420 | ||||
| 46kV | 600 | 65,000 | TR214 | 1CD04606 | 1CDT04606 | ||
| 1200 | 99,000 | 1CD04612 | 1CDT04612 | ||||
| 2000 | 164,000 | 1CD04620 | 1CDT04620 | ||||
| 69kV | 600 | 65,000 | TR216 | 1CD06906 | 1CDT06906 | ||
| 1200 | 99,000 | 1CD06912 | 1CDT06912 | ||||
| 2000 | 164,000 | 1CD06920 | 1CDT06920 | ||||
| 115kV | 600 | 65,000 | TR286 | 1CD11506 | 1CDT11506 | ||
| 1200 | 99,000 | 1CD11512 | 1CDT11512 | ||||
| 2000 | 164,000 | 1CD11520 | 1CDT11520 | ||||
| 138kV | 600 | 65,000 | TR288 | 1CD13806 | 1CDT13806 | ||
| 1200 | 99,000 | 1CD13812 | 1CDT13812 | ||||
| 2000 | 164,000 | 1CD13820 | 1CDT13820 | ||||
| 161kV | 600 | 65,000 | TR291 | 1CD16106 | 1CDT16106 | ||
| 1200 | 99,000 | 1CD16112 | 1CDT16112 | ||||
| 2000 | 164,000 | 1CD16120 | 1CDT16120 | ||||